Clean Room Equipment

Offering you a complete choice of products which include biosafety cabinet class ii type a2, biological safety cabinet, laminar air flow, vertical laminar airflow, static pass box and horizontal laminar air flow.

Biosafety Cabinet Class Ii Type A2

₹ 190000/Piece Get Latest Price

Product Brochure
BrandWIST
ModelWIST
Nominal Size4 ft
Product TypeType B2
ClassClass I
Power220
MaterialStainless Steel
Air Flow DirectionVertical
Biosafety LevelBSL 3, BSL 2
Inflow VelocityStandard
Voltage220 Voltage
PhaseSingle Phase
ColorWIST Standard
IlluminationLCD or Customer requirements
MakeWIST
Country of OriginMade in India

Minimum order quantity: 1 Piece

WST-BIO SAFETY CABINET

A Class II biological safety cabinet (BSC) is a ventilated containment device found in laboratories around the world. BSCs are used in many applications, including cell culture, pharmaceutical, clinical and microbiological work. Due to the critical nature accomplished inside these commonly used laboratory products, BSCs are regulated through rigorous standards and compliance. Engineered controls are built into the design of BSCs providing protection to the operator, product and environment

Biological Safety Cabinet

₹ 300000/Piece Get Latest Price

Product Brochure
MaterialStainless steel
Cabinet MaterialStainless Steel, Mild Steel
Main FilterHEPA Filter
Biosafety LevelBSL 2
PhaseSingle Phase Operating
FeaturesLCD controller
Voltage230 V
BrandWist
Size2 x 2 / 3 x 3 / 2 x 4 mm
Front Suction Wind Speed0.55 m +- 0.025 m/s
Overall Dimension1500 x 800 x 2100 mm (W x D x H)
Working Area Dimension1300 x 550 x 600 mm

Minimum order quantity: 01 Piece

Laminar flow Biological Safety Cabinet (horizontal/vertical) designed so as to meet the requirements of US federal standard 209 B (BS 5295) providing particle free air to meet class 100 conditions. The unit is fitted with pre-filter and HEPA filter. Air is drawn through pre-filter and is made to pass through highly effective HEPA filters having efficiency rating as high as 99.99% with cold DOP & 99.97% with hot DOP thus retaining all air-borne particles of size 0.3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced ISI marked motor of 1/5 HP capacity operates with minimum noise level. The working area is illuminated by fluorescent lighting fitted to the unit. Height of the working table provides comfortable "SIT DOWN" working position for the operator.


Salient Features

  • The cabinet is fabricated of thick wooden sheet (Optional : outer body made of mild steel duly powder coated/SS as per requirement)
  • Work table is made of SS with mirror finish which makes it easy to clean, washable & chemical resistive, corrosive free.
  • Side panels are made out of thick transparent plexus glass / acrylic sheet duly framed
  • High efficiency pre filter
  • HEPA filter efficiency- 99.99% with cold DOP & 99.97% with hot DOP thus retaining all air-borne particles of size 0.3 micron
  • Pressure manometer to guage the pressure drop in the unit
  • Built in U.V. Germicidal Light for disinfection and fluorescent light for work space illumination
  • Utility- gas/air cock and multi point electric socket.
  • Transparent front door
  • Castor wheels for ease of movement.

Laminar Air Flow

₹ 145000/Unit Get Latest Price

Product Brochure
Usage/ApplicationLaboratory
Surface FinishPolished
BrandWist
Air Flow+/- 0.1 m/s to 0.45 m/s
SizeW 1200 x D 600 x H 600 mm
Voltage230 V
Frequency50/60 Hz
Power SourceElectric

Vertical Laminar Airflow

₹ 260000/Piece Get Latest Price

Product Brochure
BrandWIST
Usage/ApplicationLaboratory
MaterialSS 304/316
Size2x2x4
Height2200 mm
Surface FinishPaint Coated
Efficiency(%)99.99%
Country of OriginMade in India

Minimum order quantity: 01 Piece

WIST Laminar airflow (LAF) is a controlled airflow used in various industries, particularly in cleanrooms, laboratories, and medical facilities, to minimize contamination and maintain a sterile environment. Here's a description of laminar airflow systems: Directionality: Laminar airflow systems produce a unidirectional, uniform airflow in a parallel stream with minimal turbulence. The air moves in smooth, straight paths, typically from a high-efficiency particulate air (HEPA) or ultra-low penetration air (ULPA) filter down towards the work surface or area of interest. Filtration: The primary component of a laminar airflow system is the HEPA or ULPA filter. These filters remove airborne particles and microorganisms, such as dust, bacteria, and viruses, down to a specified size (usually 0.3 micrometers or smaller) with a high efficiency (typically 99.99% or higher). Sterile Environment: Laminar airflow creates a sterile or near-sterile environment by continuously filtering the air and removing contaminants. This is crucial in environments where contamination can compromise processes or experiments, such as in pharmaceutical manufacturing, electronics assembly, or medical procedures. Types of Laminar Flow: There are two main types of laminar airflow: Horizontal Laminar Flow: Air flows horizontally across the workspace, parallel to the floor. This setup is commonly used in laboratories and cleanrooms where products or samples need protection from contamination. Vertical Laminar Flow: Air flows vertically from the ceiling down to the floor. Vertical laminar airflow is often utilized in clean benches, biological safety cabinets, and operating rooms to create a sterile working area around the work surface. Applications: Laminar airflow systems find applications in a wide range of industries, including pharmaceutical manufacturing, biotechnology, microbiology, semiconductor fabrication, hospitals, and surgical theaters. They are used whenever a controlled, sterile environment is necessary to protect sensitive materials, equipment, or processes. Control and Monitoring: Laminar airflow systems typically incorporate controls for adjusting airflow velocity and monitoring parameters such as air velocity, temperature, and pressure. This ensures that the airflow remains within specified parameters to maintain the desired level of cleanliness. Work Area Protection: Laminar airflow protects the work area by preventing airborne contaminants from entering or coming into contact with sensitive materials, samples, or equipment. This is essential for maintaining product quality, preventing cross-contamination, and ensuring the safety of personnel. Maintenance: Regular maintenance and filter replacement are essential to ensure the effectiveness of laminar airflow systems. Filters should be inspected and replaced according to a maintenance schedule to maintain the desired level of cleanliness and efficiency.

Static Pass Box

₹ 75000/Piece Get Latest Price

Product Brochure
BrandWist
Usage/ApplicationLaboratory
MaterialSteel With Powder Coated or Stainless Steel
Model Name/NumberWTPB-30
ShapeSquare
Voltage230-380 V

Static Pass Box have an important role in sterile area to transfer the material between two different cleanliness levels aseptically. In pharmaceutical manufacturing industries, pass boxes are normally used to transfer a particular material between two areas generally of different.

Horizontal Laminar Air Flow

₹ 167000/Piece Get Latest Price

Product Brochure
TypeHorizontal
Surface FinishPowder Coated
BrandWIST
Usage/ApplicationLaboratory
MaterialStainless Steel 304/316
ShapeRectangular
Voltage230 V
FeaturesPID Based
Noise Level65 db
WeightApprox 75 kg
Power SupplyElectric

Minimum order quantity: 01 Piece

Horizontal Laminar Air Flow Flow Cabinets receive their name due to the direction of air flow which comes from above but then changes direction and is processed across the work in a Horizontal Laminar Air Flow direction. The constant flow of filtered air provides material and product protection.

X

Contact Us

Shaikh Shahid (Managing Director)
World Invent Scientific Technology Private Limited
plot no 14, sector 1 gauraipada police station road
Rajawali, Vasai - 401208, Palghar, Maharashtra, India

Get Directions
Send Email
Share:
Thank youYour Enquiry has been sent successfully.